TBL0550-1 TekBox
EMC Test Equipment
0 to DC 60 V Line Impedance Sstabilisation Network LISN, frequency range : 100 kHz – 150 MHz.
| RENTAL | 74 € /week* | ||||
| SALE |
|
||||
Specifications : TBL0550-1 TekBox
Line Impedance Sstabilisation Network LISN :
- Frequency range : 100 kHz – 150 MHz,
- DC Resistance : < 7 mΩ Source+ to DUT+ ; < 2 mΩ Source- to DUT,
- Maximum current : 50 A continuous, 70 A for 3 minutes,
- Nominal operating voltage range : 0 – 60 Vdc,
- Component rating : 250 V,
- High current plug/screw terminals – male : Phoenix Contact 1998933, female: Phoenix Contact 1967375,
- 1 µF capacitor can be disconnected internally by removing a jumper,
- Nist traceable calibration data / certificate,
- Dimensions: 120 mm x 100 mm x 225 mm (270 mm including ground brackets),
- Weight: 1.6 kg.
Available options TBL0550-1 TekBox
| CAL | Standard Calibration | 225 € |
Download the technical documentation TBL0550-1 TekBox
Watch the presentation video TBL0550-1 TekBox
The TBL0550-1 5µH LISN is a device required to setup conducted noise measurements of DC-powered electronic equipment.
It is designed to be used for measurements in the frequency range of 150 kHz to 110 MHz according to CISPR 16-1-2, CISPR-25, EN55025, MIL-STD-461F, ISO11452-4 and with limitations DO-160/ED-14G and ISO 7637-2.
The LISN is inserted into the supply line of the DUT (Device Under Test). Conducted noise which is present at the supply terminals of the DUT can be measured at the BNC connector using a spectrum analyzer or a measurement receiver. The source (supply) terminal and the DUT terminal are decoupled by a 5 µH inductor.
Two TBL0550-1 in combination with the Tekbox LISN Mate enable separate measurements of common mode and differential mode noise.
The unit comes equipped with a BNC-male to N-male RG232 cable, mating connectors and ground brackets to attach it to a ground plane.