TBCDN-M3 TekBox

EMC Test Equipment

Coupling Decoupling Networks (CDN).

RENTAL 95  /week*
SALE
Brand New Price Warranty 24 month 1 170 

Set your quotation

Choice of delivery *

Options preference

Enter all the available options you want to add, separated by commas.

Quantity

Specifications : TBCDN-M3 TekBox

Coupling Decoupling Networks (CDN) :

  • Maximum supply voltage : 300 V AC, 600 V DC,
  • Maximum current : 36 A,
  • Frequency range : 150 kHz – 230 MHz,
  • Maximum RF input power : 6.5 W CW,
  • Maximum RF input voltage : 32 V
  • Common mode impedance :
    • 150 kHz – 24 MHz : 150 Ω ± 20 Ω
    • 24 MHz – 80 MHz : 150 Ω + 60 Ω / – 45 Ω
    • 80 MHz – 230 MHz : 150 Ω ± 60 Ω
    • Voltage Division Ratio : 150 kHz – 80 MHz : 9.5 dB ± 1 dB
    • 80 MHz – 230 MHz : 9.5 dB + 3 dB / – 2 dB
  • RF input connector : N – female,
  • EUT / AE connectors : 4 mm banana safety jacks, 4mm slots in base plate for GND connection,
  • Housing material : powder coated aluminium, stainless steel base plate,
  • Dimensions: 300 x 150 x 150 mm,
  • Weight : ca. 2.5 kg,
  • Included : individual test protocol with voltage division ratio and common mode impedance,
  • Optional accessories : 30mm adapter panel with shorting bars and BNC connector 50 Ω to 150 Ω N-male to N-female adapter.

Available options TBCDN-M3 TekBox

CAL Standard Calibration 225 

Download the technical documentation TBCDN-M3 TekBox

You need to be connected to consult and download the documentation

The Tekbox TBCDN-M3 is a Coupling Decoupling Network (CDN) used for conducting immunity testing according to IEC 61000-4-6.

Furthermore, the TBCDN-M3 is compliant with IEC 61000-4-6 Annex D2.

It is designed to inject common mode disturbance signals in the frequency range from 150 kHz to 230 MHz into unscreened AC and DC power supply lines.