DC Power Supplies

N6781A Source/Measure Unit for Battery Drain Analysis, 2-Quadrant, 20V/1A or 6V/3A, 20W.

RENTAL 225  /week*
SALE
Brand New Price Warranty 36 month 6 850 

Set your quotation

Choice of delivery *

Options preference

Enter all the available options you want to add, separated by commas.

Quantity

Specifications : N6781A Keysight / Agilent

N6781A Source/Measure Unit for Battery Drain Analysis, 2-Quadrant, 20V/1A or 6V/3A, 20W :

Output Ratings :

  • Voltage: up to 20 V,
  • Current: up to ±3 A,
  • Power: 20 W.

Programming Accuracy (at 23°C ± 5°C after 30 minute warmup; applies from min. to max. program) :

  • voltage, 20 V range: 0.025% + 1.8 mV,
  • voltage, 6 V range: 0.025% + 600 µV,
  • current, 3 A and 1 A ranges: 0.04% + 300 µA,
  • current, 300 mA range: 0.03% + 150 µA,

Transient Response :

  • < 30 mV of droop in response to 0.15A / µs current transients

Measurement Accuracy (at 23°C ± 5°C) :

  • voltage, 20 V range: 0.025% + 1.2 mV*
  • current, 3 A range: 0.03% + 250 µA*
  • current, 100 mA range: 0.025% + 10 µA*
  • current, 10 µA range: 0.025% + 8 nA